Data Center


Basic Facts


VeratNet's Data Center is one of the most modern facilities of this kind in the country. It is projected according to modern trends of ANSI-TIA standards for facilities of this kind, and is situated within the VeratNet’s commercial building in 37 Vojvode Misica Boulevard.

  • Guaranteed redundancy of all systems (UPS equipment, air conditioning, network wiring ...)
  • High quality components
  • Reliability and availability of 99.999%
  • 55 cm high floor
  • Local redundant cabling and floor cooling located below the floor
  • Optimal temperature for equipment functioning
  • Internal cabling with redundant fiber optic cables
  • Users connected to all international Internet links available in the country
  • Equipment located in 42U racks
  • Highly sophisticated system of surveillance
  • 24 / 7 video surveillance system with restrictive access control
  • Modern fire detection system
  • Senior level administrators are always available for the highest possible level of support


Electricity supply


  • The system secured with 2 +1 redundancy (MGE Galaxy 5000 100kVA UPS)
  • 400 kVA Caterpillar diesel – started automatically in case of power cuts
  • Uninterruptible power supply and a minimum possibility of power failure


Access Control and Video Surveillance


We provide you with the highest level of security to your equipment, 24 hours a day. With multiple levels of security, entering the data center is controlled by proximity cards and access codes.

  • No public access to the data center is available
  • Alarm system for intrusion detection
  • Full motion video camera
  • Constant supervision of entrance and data center
  • The card and access code required to enter the data center
  • Database of individuals with access control
  • Man Trap Security - only authorized personnel can enter the data center
  • 24/7/365 monitoring
  • 6 APC NetBotz surveillance cameras
  • Locked racks for every server
  • Registration of equipment serial numbers
  • Emergency access for all customers with priority
  • Electronic record of every access
  • Overseeing the environment to prevent damage to equipment


Fire-extinguishing System


VeratNet's data center is protected by fire systems in two zones. System FM200 fire extinguishers without the use of water allow the best possible fire protection.

  • The system for fire detection in two areas
  • Photoelectric smoke detectors for early warning
  • Warning heat systems as a secondary system of protection
  • FM 200 fire alarm system - based on a harmless gas
  • Fire extinguishing systems with double dry tube
  • Water - outside the critical equipment area
  • The sprinklers do not damage the equipment
  • Alarm system without the possibility of error - prevents false activation or a mistake
  • Activation of the pre-action, specific to a particular zone
  • Smoke tube in accordance with regulations

For any information you can contact us on telephone number: 011 360 5 360, or by e-mail: business@office.verat.net.